Scheduled Maintenance (Every 250 - 500 Hours)
Cylinder Drift Test: This tests the health of the internal piston seals.
Curl the bucket fully into the dump position (cylinder fully extended).
Shut down the engine and carefully release hydraulic pressure in the bucket circuit (follow the operator's manual for safe procedures).
Place a reference mark or measure the exposed rod length.
Monitor the cylinder for 10-15 minutes.
Any significant retraction (drift) indicates that oil is leaking past the internal piston seals. This reduces efficiency, wastes energy, and is a clear sign that a rebuild is needed.
This 590-8057 bucket cylinder is used 374D 374F excavator.
EXCAVATOR
374F 374F L






Related Part Number:
3V-2431
4I-6330
6V-8223
8T-8894
9X-8399
095-1280
095-1731
102-0786
102-2244
147-5738
147-5771
147-5776
165-9294
177-9754
188-2199
212-0907
214-1639
215-1942
357-5257
243-3177
300-8784
9X-3401
363-9311
367-3928
367-3929
493-3133
198-5529
7Y-0468
493-3136
6E-0813
128-9261
102-8804
3E-3377
424-2919
8C-9179
8T-8737
9X-1386
9X-1386
370-1940